Options and Accessories | Thermal Platforms

Click me! 

Clamping & Mounting

thermal stream

Click me!

Coolant Delivery & Exhaust 

Click me!
Sensor Types & Logger

Click me!

Controllers Options 

Click me!

Purge & Cover 

Read More About:

.

Clamping & Mounting Options

Heavy Duty Clamps

Cryogenic platform

Light Duty Clamp

Medium Clamp

Clamp set, Kopal Clamp, Piccolo,

thermal chamber window

Light Duty Two Point Clamp

Adjustable Toggle Clamp

thermal chamber

Custom Adapter Plate

An array of 4-40 holes in a quarter inch thick plate attaches to Thermal Platform surface

SD49HDC (Heavy Duty Clamp)

hot/cold plates

Custom Adapter Plate

Used in Microbiological research for attaching beakers to a Thermal Platform

.

Coolant Delivery Hoses & Exhaust

 

For use with cryogenic fluids. Liquid Nitrogen and Liquid Carbon Dioxide require different hose configurations

Liquid Carbon Dioxide  Hose

For use with L-CO2 Dewars, bulk systems or high pressure syphon tanks

Liquid Nitrogen Vacuum

Jacketed Hose

For use with Dewars or bulk systems. Comes with Pressure Relief Valve for added safety

thermal stream

Armored Liquid Nitrogen Hose

For use with Dewars or bulk systems. Comes with foam insulation & Pressure Relief Valve for added safety

Thermal Platform Exhaust Hose

For use with all models and standard temperature Ranges -100°C to +200°C (-148°F to 392°F) SD288 requires our 3/4 Inch hose

vibration testing machine

Candy Cane Riser 

Liquid Nitrogen Hoses that have a Safety PRV (Pressure Relief Valve) Port. Points the PRV downward  so moisture doesn’t accumulate in the valve, prevents possible freezing.  An added benefit is the pressure when relieved points downward.

MIL-STD-810

Super Quiet Muffler (SQM)

 

Greatly reduces the noise level and dampens the pitch of coolant being spent by a Thermal Platform

Super Quiet Vent Valve

For use with cryogenic Dewars. Greatly reduces the sound of the tank venting built up pressure

Wye Connector 

Connect two Liquid Nitrogen Hoses to a single source

Wye Connector

 

Connect two L-CO2 hoses to a single source

.

Temperature Sensors & Loggers

Our Temperature Controllers offer the ability to read several different types of sensors including RTDs & Thermocouple

Many Sensors are available for extended temperature ranges or designed for space simulation applications

3 Wire 100Ω Platinum RTD 

Two standard sizes of tubular probes with Aluminum Sheath, 0.188 Inch Diameter

3 Wire 100Ω Platinum Surface Mount RTD

Very low mass sensor with a 0.1 Inch Diameter hole for securing to a device under test 

3 Wire 100Ω Platinum Surface Mount RTD

Rugged flag style sensor with a 0.1 Inch Diameter hole for securing to a device under test 

3 Wire 100Ω Platinum Surface Mount RTD

No. 4 socket head cap screw counter-bored mounting through hole for securing to a device under test 

3 Wire 100Ω Platinum Surface Mount RTD

No. 8-32 threaded stud  for securing to a device under test. Many available stud sizes

3 Wire 100Ω Platinum Surface Mount RTD

Very thin low mass Kapton Tape Sensor is available as a thermocouple or a 2 wire RTD

 Surface Mount Thermocouple Block

No. 4 socket head cap screw counter-bored mounting through hole for securing to a device under test 

Surface Mount Thermocouple Lug

No. 6 screw lug is used for securing to a device under test 

In-line Sensor Connector

Shown here is a Type T in line connector, part of the controller umbilical and is available for all types of RTD’s and Thermocouples.

 3 Wire RTD Terminal Block

Screw down terminations allow the controller to be removed without removing the external sensor

 3 Wire RTD Terminal Block

Press locking terminations in the back to keep lid area clear for large unit under test or HDC (Heavy Duty Clamp)

Cryogenic platform

 3 Wire RTD Terminal Block

Top mounted press locking terminations for convenient connection to external sensor

[/qodef_elements_holder]
thermal chambers

16-Channel Temperature Monitor

Uses Thermocouples, daisy chain up to four of these 16-Channel monitors together and acquire 64 temperatures on the Unit-Under-Test. The TotalTemp Technologies Synergy Nano Temperature Controller displays and logs these readings to the internal log file for analysis, graphing and reporting

.

Controller Options and Accessories

 Benchtop Controller 

Our standard option for the Synergy Nano Controller

19 Inch Rack Panel

Rack panels designed to house 1 or 2 Temperature Controllers

GPIB Communication Option

 Control instruments using GBIP protocols. Free Labview Drivers Available Click Here

Retrofit versions available!

Finally sustainability for tired equipment.  See Fix it or replace it  for more on retrofit controllers for aging systems.

Retrofit versions available!

Synergy Nano installs quickly with all the traditional connections.   See Fix it or replace it  for more on retrofit controllers for aging systems.

Long Umbi or Power Cord

Optional extended length umbilical and or power cord. Shown here is an 8 Foot umbilical

Two channel feature 

The Synergy Nano Controller can run two platforms separately or together, housed in one chassis or separated into two separate chassis

Digitally Controlled 

Thermostatic Outputs

 Synergy Nano on/off function based on actual temperatures to indicate when hot or cold. Read More about these features in the Application Notes. Model Shown SD288.

digital temperature controlled hot plate

Network Plotting

This  replaces chart recorders by creating PDF files that go directly to a users network.  Requires a key code for the software upgrade, contact us for the code

thermal platforms

 Cascade Control Feature

Smarter Synergy Nano software achieves better & faster temperature control. Requires an external sensor and a code. Contact us for a key-code

digital temperature controlled hot plate

Free Synergy Controller Features

Logging Function – Importing to Excel for Graphing – Streamline the process

See Application Notes  for further details of this Synergy Nano powerful feature

Synergy Nano Controller Free Video

Many highlights of the powerful features packed into our premier controller. Click the image above for more information

.

.

Purge Options and Accessories

 

Purging with gas serves two purposes during environmental thermal testing. Most often it is used to keep condensation and frost from accumulating on the surfaces of the DUT (Device Under Test) at cold temperatures. Additionally it is also used to prevent oxidation of metals surfaces at high temperatures

Probing Covers are available for all sizes of Thermal Platforms

Purging serves three purposes. Most often it is used to keep condensation and frost from accumulating on the surfaces of the DUT (Device Under Test) at cold temperatures. Additionally it is also used to prevent oxidation of metals surfaces at high temperatures. Lastly the cover greatly reduces the gradient effects caused by room temperature 

LOW ESD SD/SC144 Polycarbonate Probing Cover

Some users require LOW ESD Polycarbonate, standard clear is available and more affordable.

Shown on a SC144 mechanically cooled Thermal Platform with a standard hinged lid, modified internal dimensions to accommodate heavy duty clamp

T-vac

Custom Lift Off Covers

 Above Image: Thermal Platform with LOW ESD Cover, designed for a Shaker Table. 

SD49 Low ESD lift off cover in a Microbiology Laboratory Microwave Oven 

Flow Meter

Flow meter comes with press lock fitting and 12 feet of tubing. For use with gas sources with regulated pressure

Panel Mount Flow Meter

Flow meter can be panel mounted. Installed in 19″ rack, benchtop controller or on purge cover

Dry Nitrogen Purge Regulator with Flowmeter

Regulates pressure and flow rate of gaseous Nitrogen from a Dewar or portable tank. Works very well because the moisture content of the Nitrogen is extremely low and it is often readily available at the test station. Nitrogen is also notably inert, that is to say it does not easily react with other elements or materials. Ships with 12 Feet of tubing and press lock connections installed when ordered with a Purge Cover

Purge Conditioning Option

This simple solution gets the air temperature inside a cover close to the platform temperature which is very beneficial for reducing thermal gradients. Purge gas is run through an extra heat exchanger in the platform as indicated with arrows; this gives the user the ability to keep the temperature of the purge gas much closer to the temperature of the device under test. Available on all models of Thermal Platforms and HBC Models (Hybrid Benchtop Chambers

TotalTemp Technologies, Inc.

 

 

 

Tel: 888-712-2228
[email protected]
[email protected]

thermal platforms